Customization: | Available |
---|---|
Type: | Balancing Machine |
Sample Feeding: | Dry Dispersion |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model No. | CY-901 | ||
Executive standard | GB/T 19627-2005/ISO 13321:1996 ;GB/T 29022-2012/ISO 22412:2008 | ||
Measure range | 1-10000nm (reference to sample) | -500mV - +500mV | |
Concentration range | 0.1mg/ml--100mg/ml (reference to sample) | ||
Electrophoretic mobility range | > ±20μm.cm/V.s | ||
Highest conductivity | 200mS/cm (reference to sample) | ||
Accuracy error | <1% (National standard sample D50 value) | <10% (Standard sample) | |
Repeatability error | <1% (National standard sample D50 value) | <10%(Standard sample) | |
Laser Source | Semiconductor laser λ= 635nm,P=1-40mw (adjustable) | ||
Detector | Photomultiplier tube | ||
Scattering angle | 90o | 18o | |
Sample cell volume | 10mm*10mm*40mm, 1--4mL | 10mm*10mm*60mm, 1mL | |
Temperate range | 5-45ºC | ||
Temperature control accuracy | 0.1ºC | ||
Test speed | <5 Min | ||
Digital correlator | Model | HA1024 | HA1024 |
Auto-correlation channels | 892 | 892 | |
Baseline channel | 4 | - | |
Physical channels | 5000 | - | |
Unit delay time | 1µs-10ms(adjustable) | 1µs-10ms(adjustable) | |
Outer dimension | 560mm*450mm*300mm | ||
N.W. | 20Kg |
Test principle | Using the principle of electrophoretic light scattering and photon correlation spectroscopy, the size of particle Zeta potential was determined according to the electrophoretic movement speed of particles in liquid. The population velocity of the electrophoretic motion of the particles, and the amount of Doppler shift of the scattered light caused by the laser irradiation of these particles, varies. Photon correlation spectroscopy analyzes the size of particle Zeta potential according to the frequency shift. |
Ultra-high-speed data acquisition | The core component of the instrument is through the HA1024 digital correlator, which can complete the collection of electrophoretic scattered light intensity and the calculation of the auto-correlation function in real time, so as to effectively reflect the information of the electrophoretic movement speed of the particles and lay the foundation for the accuracy of the Zeta potential test results. |
High sensitivity signal-to-noise ratio | Using professional-grade high-performance photomultiplier tubes, it has extremely high sensitivity and signal-to-noise ratio to photon signals. |
High-precision constant temperature control | Using semiconductor temperature control technology, the temperature control accuracy is as high as 0.1 °C, so that the sample is always in a constant temperature state during the whole test process, avoiding the test deviation caused by the change of liquid viscosity and Brownian motion caused by temperature changes, and ensuring the accuracy and stability of the test results. |
Stable optical path system | The optical path system constructed by the optical frequency shifting device and the optical fiber coupling technology makes the detection system not only small in size, but also has strong anti-interference ability, thus ensuring the stability of the test. |