• Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test
  • Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test
  • Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test
  • Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test
  • Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test
  • Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test

Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test

After-sales Service: Lifelong
Warranty: 1 Year
Max Diameter of Workpiece: <500mm
Mass Scope of Workpiece: <900kg
Type: Balancing Machine
Maxcapacity: >1000KN
Customization:
Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Packaging & Shipping
  • Our Advantages
  • FAQ
Overview

Basic Info.

Model NO.
CY-306B
Accuracy Grade
0.5
Load Way
Electronic Load
Loading Method
Dynamic Load
Display
Needle
Control
Computer Control
Weight
0-100Kg
Power Source
AC220V
Oil Cylinder Position
Under
Parameters of The Project
Technical Specifications
Swing Arm Length
100mm
Load Arm Length
50mm±0.1mm
Test Speed
Load Arm Length
Nominal Bending Angle
±7.5° and ±15°
Transport Package
Carton
Specification
75cm*65cm*70cm
Trademark
CYEEYO
Origin
Shan Dong
HS Code
9027500090
Production Capacity
100

Product Description

          lab equipment Bending Tester Cardboard Paper Taber Stiffness Test
Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test
Lab Equipment Bending Tester Cardboard Paper Taber Stiffness TestProduct Description

CY306 cardboard stiffness tester (also known as cardboard stiffness instrument,
paper stiffness meter, stiffness meter) is the international standard generic 
Tai Boer (Taber)-type stiffness tester, main technical parameters of the instrument
in line with national standards and the relevant provisions of international standards. Stiffness is a measure of bending strength of paper and cardboard targets, Tai Boer-type instrument is to measure the stiffness index of the instrument, Taberstiffness is the static bending strength indicators.

 

Feature
1. Taber stiffness tester is based on the static torque on the shaft center of the design principles of balance. By measuring the sample is clamped at one end was bent to the angle required for a given force or torque, to get the value of the sample stiffness. Specimen bending force is acting on a curved length of the same.
2. Taber stiffness loading instrument is based on two principles of law and the torque balance design special test equipment.Equipment from the transmission part, measure part and supporting part of a combination of installed base.
3. drive through the middle part of the drive chain from the motor to the angle plate, angle plate frame rotating drive to push the paper work.
4. measured in part by the intensity of plate, angle plate, put the diamond body, Paper Holder, aircraft and other pieces of paperto push the composition. Motor rotation angle plate, angle plate on the frame to push the paper along with rotation, pushing the paper to push the shelf paper contact with the specimen small round rod bent over the sample. Sample holder in the Paper Holder jaw, while the jam is installed in the diamond body swing, rigidity in the sample under its own power, while the diamond sample placed under the body has been the role of torque in the torque effect hem body pushed rotation, 
when the pendulum relative to the body and angle plate angle to 15 ° (or 7.5 °) to stop, then the system to achieve torque balance. Angle plate zero line will indicate the kind of torque values to be tested to mN · m said.

 

Application
Applying in testing stiffness and resiliency of paper and cardboard (thickness ≤1mm) according international Taber method.

 

Standard
1.GB/T  2679.3   board stiffness test
2.ISO  2493   Paper and board Determination of stiffness

 

Parameter
Measuring range is (1 ~ 500) mN · m, the entire measuring range is divided into seven files, the file sub-file re-thallium diskindexing quality and intensity values as follows:

Range

(mN·m)

The quality of sub-file re-thallium

    Efforts to set indexing the value    

(mN·m)

Number

  Quality  (g)

1~5

1

5.098

0.05

1~10

2

10.197

0.10

1~20

3

20.394

0.20

5~50

4

50.986

0.50

10~100

5

101.972

1.00

20~200

6

203.944

2.00

50~500

7

509.860

5.00

Note:1mN·m=10cN·cm

Main indicators:

Parameters of the project

Technical Specifications

Indication
Accuracy

Indication error

± 2% (upper limit of the range measuring 10% to 90% range)

Indication ofchanges in

≤ 2% (upper limit of the range measuring 10% to 90% range)

Swing arm length

100mm

Load arm length

50mm±0.1mm

Test speed

200°/min

Nominal bending angle

±7.5° and ±15°

Sample size (L×W)

70mm×38mm

Dimensions (L×W×H)

270mm×165mm×355mm

Weight

16kg

Packaging & Shipping

Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test

Our Advantages

Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test

FAQ

Lab Equipment Bending Tester Cardboard Paper Taber Stiffness Test

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2020

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
10000000 RMB
Plant Area
1001~2000 square meters