Customization: | Available |
---|---|
After-sales Service: | Lifelong |
Warranty: | 1 Year |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Characteristics
Work principle: The laser particle size analyzer is based on full measuring range of Mie scattering theory, sufficiently considering the optics nature such as sample and decentralized medium refraction coefficient and so on. On the basis of laser illuminate size and the size distribution regular pattern of scattering light energy that comes from the sample inversely calculate out sample group.
Technique feature: The laser particle size analyzer work principle is well-developed, hardware design is very reasonable, the product is designed according to the international engineering standard ISO-13320, GMP Regulation and FDA/21CFR 11 absorbs England, America, Germany and other countries well-developed experience on the size analysis, all features of the product are domesticly and leading.
Illuminant: The laser particle size analyzer adopts He-Ne's laser make illuminant, the wavelength is 0.6328 micron, wavelength is short, string breadth is narrow, stability is good, and laser power source and laser tube service life is more than 25000 hours.
Light electricity probe: The laser particle size analyzer light electricity system is designed uniquely. The primary detector is one, many assist detectors presenting non-uniform intercourse and three dimension fan-shaped ranges matrix rank. The largest test examination horn angle attainability is up to 135°
Light route: The laser particle size analyzer adopts a measuring range designed, the convergent light route is unique, decreasing Fourier lens, as a result the measurement range broader, the resolution is higher, the error is minimal.
Specifications
|
Dispersion method |
Specifications |
Dimensions |
Weight(Net) |
CY-2002 |
Wet |
1,measurement range:0.1-800μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
1000×330×320mm |
38kg |
CY-2006 |
Wet |
1,Measurement range:0.05-1200μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
||
CY-2008 |
Wet |
1,Measurement range:0.02-2000μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
||
CY-2009 |
Wet |
1,Measurement range:0.02-2600μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
|
|
CY-2012 |
Dry |
1,Measurement range:0.1-800μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
Main system: 1000×330×320mm Dry sampling system:350×330×300mm |
40kg |
CY-2016 |
Dry |
1,Measurement range:0.1-1200μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
||
CY-2018 |
Dry |
1,Measurement range:0.1-2000μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
||
CY-2019 |
Dry |
1,Measurement range:0.1-2600μm 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
||
CY-2022 |
Wet/ Dry |
1,Measurement range:0.1-800μm/ 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
Main system: 1000×330×320mm Dry sampling system:350×330×300mm Wet sampling system:350×330×300mm
|
50kg |
CY-2026 |
Wet/ Dry |
1,Measurement range:0.05-1200μm(wet) 0.1-1200μm(dry) 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
||
CY-2028 |
Wet/ Dry |
1,Measurement range:0.02-2000μm(wet) 0.1-2000μm(dry) 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
||
CY-2030 |
Wet/ Dry |
2,Measurement range:0.02-2600μm(wet) 0.1-2600μm(dry) 2,Error:<±1%(national standard materials D50) 3,Repetitiveness deviation: <±1%(national standard materials D50) |
User-Friendly Operation:The operation is standard, quantized and simple .And it takes short time to master it. The data are tested within 1 minute.
High Viewability:The test software is user-friendly. The test processes are readable and instantly refresh. The operators observe at any time the instrument's situation and the changes of the test data, and analysis reality and reliability of the test data. In the intelligent touch panel, there are operating keys for circulation, ultrasonic, stir and discharge. Due to the standard, quantized and simple operation, the test time is shortened and the requirement for the operators are lowered.
Applied Range
All kinds of metal powder: aluminite powder, zircon powder, nickel powder, tungsten powder, tin powder, zinc powder, molybdenum powder, magnesium powder, copper powder, rare metal powder, alloy powder, metallic oxide powder( exclusive of magnetic powder), etc.
All kinds of nonmetal powder: talc powder, kaolin, calcium carbonate, , fluorescent powder, calcite, diamond, barite, fluorite, zeolite, boron carbide, clay, graphite, quartz, gypsum, bentonite, kieselguhr, zirconium silicate, corundum, mica, titanium.
Others: soil, dyestuff, brenstone, explosive, western medicine, Chinese medicine, agricultural pesticide, grinding material, coatings, food additive, catalytic agent, concrete, river silt, oil drop, air bubble, emulsion.