TECHNICAL SPECIFICATIONS
Measurement range: 0-50% (the maximum measurement range is when the material is saturated with
water)
Static accuracy: ±0.1%
Measurement accuracy: ±0.2% (change in material composition will cause measurement error)
Measurement channels: 50
Height range: 250mm±100mm
Operating temperature: 0-50ºC
Operating humidity: 5-90%
Repeatability: 0.1%
Response time: 0-60 seconds
Filter range: 0-2.5%
Power supply: AC 110-240V 50Hz/60Hz
Power consumption: 150W
Light interference: not affected by changes in external light and no need for a hood over the probe
Temperature influence: With automatic temperature offset function, it is basically not affected by changes
in external temperature
The probe should be installed in an easily accessible place. First, it should be easy to sample under
the probe and easy to maintain (such as wiping windows, cleaning surfaces, etc.);
(1) The machine should be installed in a safe position for measuring where the material to gauge will not
have direct contact with the probe;
(2) probe installation height and direction: (see Figure 2.1) The probe is to be installed over a certain
material that is not fragmented as on a conveyor belt or a vibrating conveyor. Note that the material must
at least demonstrate a thickness of 10mm (recommended 15mm above) in order to completely ignore the
conveyor belt as a source of possible confusing effect in the background.
(3) In order to allow for a longer period of time for the material to reach a state of balance before taking
measurements, the probe of the dryer or other equipment for adjustment is preferably installed as far as it
can be from the steam outlet;
(4) It is a basic requirement for the production line to ensure that the material to measure embraces a
certain degree of consistency and continuity in the production process;
(5) The consistency of the material has a great influence on the measurement accuracy compared with the
oven drying method, especially on the latter's double-sampling deviation.